Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Dual Run & Start Capacitor ...
OEM Payne Dual Run & Start Capacitor Kit for PA4RNG036000BAAA
Payne

OEM Payne Dual Run & Start Capacitor Kit for PA4RNG036000BAAA

SKU: PAYNE-PA4RNG036000BAAA-CAPACITOR-P291-5053RS Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne Dual Run & Start Capacitor Replacement Kit for Model PA4RNG036000BAAA

This OEM capacitor kit includes both the P291-5053RS Dual Run Capacitor and the P281-8806 Start Capacitor — the factory-specified replacements for the Payne PA4RNG036000BAAA 3-ton split-system air conditioner. The dual run capacitor maintains steady operating voltage to both the compressor and condenser fan motor, while the start capacitor delivers the extra electrical boost needed to kick the compressor into motion. When either component fails, you may experience a humming condenser with no motor rotation, intermittent short-cycling, a tripped breaker, or a system that simply refuses to start on warm days when electrical demand peaks.

  • Specs: P291-5053RS — Dual Run Capacitor, round case, 370V/440V rated, factory-matched MFD tolerance ±3% | P281-8806 — Start Capacitor, high-capacitance boost design, matched to PA4RNG036000BAAA compressor start requirements
  • OEM vs Generic: OEM capacitors are manufactured to exact Payne/ICP factory tolerances. Aftermarket generics often carry ±10% MFD variance, which increases thermal stress on the compressor and condenser fan motor, shortening their operational lifespan significantly.
  • Install Difficulty: 2/5 — Always discharge the capacitor fully before handling — stored voltage can exceed 300V even after shutdown. Tools needed: 1/4" nut driver, insulated needle-nose pliers, multimeter with capacitance function. Photograph all wiring connections before disconnecting terminals. Replace one capacitor at a time to avoid wiring confusion.
  • Warranty: 1-year OEM factory warranty covers defects in materials and workmanship. Orders placed before cutoff ship same business day from our climate-controlled parts warehouse.

Compatibility & Ordering: This kit is factory-matched to the Payne PA4RNG036000BAAA 3-ton (036) split-system condenser. Always cross-reference the MFD and voltage ratings on your unit's data plate before installation to confirm fitment. The PA4RNG036 series is also sold under related ICP, Heil, and Tempstar badge equivalents — contact our fitment team if you need cross-brand verification. In stock and ready to ship — order today for same-day dispatch.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Payne PA4RNG036000BAAA?
Yes. This is the factory-specified OEM capacitor for the Payne PA4RNG036000BAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Payne PA4RNG036000BAAA?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.