OEM Payne 2-Pole Contactor 24V Coil for Model PA4ANG030000BCAA

This OEM replacement contactor (part number HN51KC024) is the factory-specified high-voltage relay for the Payne PA4ANG030000BCAA split-system air conditioner. The contactor acts as the primary switching device that allows 240V power to reach the compressor and condenser fan motor when the thermostat calls for cooling. A failed contactor is one of the most common causes of an AC unit that hums but won't start, fails to energize at all, or runs continuously without shutting off due to welded contacts.

  • Specs: 2-pole configuration | 24V control coil | Factory-rated amperage for 3-ton residential split systems | Direct OEM replacement for part number HN51KC024
  • OEM vs Generic: This OEM contactor is built to exact Payne/Carrier factory specifications, including coil pull-in voltage and contact material quality. Generic contactors may use inferior silver-alloy contacts that pit and weld prematurely, causing dangerous continuous compressor operation.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and verify zero voltage with a multimeter before touching any terminals. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removal.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our climate-controlled warehouse.

Compatibility: Designed as a direct drop-in replacement for the Payne PA4ANG030000BCAA split-system condenser. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — reach out before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA4ANG030000BCAA?
Yes. This is the factory-specified OEM contactor for the Payne PA4ANG030000BCAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA4ANG030000BCAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.