OEM Payne 2-Pole Contactor 24V Coil for Model PA3ANA060000BBAA

This is the OEM factory-specified contactor (part# HN52PD024) for the Payne PA3ANA060000BBAA split-system air conditioner. The contactor acts as a high-voltage relay — when your thermostat calls for cooling, the 24V control board energizes the contactor coil, which closes the high-voltage contacts and powers the compressor and condenser fan motor. A failed contactor is one of the most common reasons an AC unit receives a call for cooling but simply won't start. Symptoms include a completely unresponsive outdoor unit, a buzzing or chattering sound at the contactor, or pitted/burned contacts visible on inspection.

  • Specs: 2-pole configuration | 24V AC coil voltage | Rated for high-amperage compressor loads | Direct OEM replacement, part number HN52PD024
  • OEM vs Generic: OEM contactors feature factory-matched coil sensitivity and contact surface ratings. Generic contactors frequently use lower-grade contact materials that pit and weld prematurely, especially during high-load summer operation.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and verify voltage is zero before touching any wiring. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removal.
  • Warranty: 1-year OEM factory warranty included. Orders placed by 3PM ship same business day from our stocked warehouse.

Compatibility: Engineered specifically for the Payne PA3ANA060000BBAA 5-ton split-system condenser. Verify your existing contactor's pole count and coil voltage against your unit's data plate prior to ordering. Our HVAC parts specialists are available to confirm fitment before you purchase — same-day shipping means your system is back online fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA3ANA060000BBAA?
Yes. This is the factory-specified OEM contactor for the Payne PA3ANA060000BBAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA3ANA060000BBAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.