Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA1SPA102000AAAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA1SPA102000AAAA

SKU: PAYNE-PA1SPA102000AAAA-CONTACTOR-HN53CD024 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne Contactor 2-Pole 24V Coil for Model PA1SPA102000AAAA

This is the factory OEM replacement contactor (part# HN53CD024) for the Payne PA1SPA102000AAAA air conditioning system. The contactor is a high-voltage relay controlled by your thermostat's 24V signal — when the thermostat calls for cooling, the contactor closes its poles to send line voltage to both the compressor and condenser fan motor. A failed contactor is one of the most common reasons an AC unit appears completely dead: the indoor air handler runs normally, the thermostat calls for cooling, but nothing happens at the outdoor unit. You may also notice the system failing to shut off (welded contacts) or hear a loud chattering or buzzing from the contactor coil.

  • Specs: 2-pole design | 24V AC coil voltage | Factory-rated amperage | Direct OEM replacement per Payne spec — no modification required
  • OEM vs Generic: OEM contactors like this HN53CD024 use factory-grade silver-alloy contact tips rated for thousands of switching cycles. Generic contactors often use lower-grade contacts that pit and weld prematurely, leading to repeat failures within a single season.
  • Install difficulty: 2/5 — Shut off all power at the disconnect box and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers. Photograph all wiring connections before removing the old contactor. Always verify power is off with a non-contact voltage tester.
  • Warranty: 1-year OEM factory warranty. Orders received by 3PM local time ship same business day from our warehouse.

Compatibility: Engineered specifically for the Payne PA1SPA102000AAAA condensing unit. Confirm your existing contactor's pole count and coil voltage from the data plate or wiring diagram inside the unit's access panel before ordering. Our parts specialists are available to verify fitment — reach out before you order if you have any questions. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA1SPA102000AAAA?
Yes. This is the factory-specified OEM contactor for the Payne PA1SPA102000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA1SPA102000AAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart