Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA17NA03600GBAAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA17NA03600GBAAA

SKU: PAYNE-PA17NA03600GBAAA-CONTACTOR-HN51KC024 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor HN51KC024 for Model PA17NA03600GBAAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Payne PA17NA03600GBAAA split-system air conditioner. The contactor is the high-voltage relay that receives a 24V signal from the thermostat and closes the circuit to energize the compressor and condenser fan motor. When the contactor fails, common symptoms include the outdoor unit not powering on at all, the unit running continuously without cycling off, or visible pitting and burning on the contact points that prevent reliable switching.

  • Specs: 2-pole configuration | 24V AC coil voltage | Compatible with R-410A systems | Factory-matched contact rating for the PA17NA036 platform — verify amperage on your unit data plate before ordering
  • OEM vs Generic: OEM contactors like this HN51KC024 use factory-grade silver-alloy contact points engineered for the exact current loads of the PA17NA03600GBAAA. Generic contactors frequently use lower-grade contacts that pit faster under cycling loads, leading to premature failure and compressor damage.
  • Install difficulty: 3/5 — Always disconnect power at the disconnect box and verify zero voltage with a multimeter before touching any wiring. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, wire labels or tape. Photograph all wiring connections before removing the old contactor.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed by 3 PM local time ship same business day from our stocked warehouse.

Compatibility: Engineered specifically for the Payne PA17NA03600GBAAA single-stage split-system condenser. Always cross-reference the OEM part number HN51KC024 and confirm coil voltage and pole configuration against your unit's data plate before installation. Not sure it fits? Our HVAC parts specialists verify fitment before you order — contact us anytime.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA17NA03600GBAAA?
Yes. This is the factory-specified OEM contactor for the Payne PA17NA03600GBAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA17NA03600GBAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.