Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA14NC024000AAAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA14NC024000AAAA

SKU: PAYNE-PA14NC024000AAAA-CONTACTOR-HN51KC024 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor 24V Coil for Model PA14NC024000AAAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Payne PA14NC024000AAAA split-system air conditioner. The contactor is a high-voltage relay that receives a low-voltage (24V) signal from the thermostat and closes to send 240V power to the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a burned coil, or a stuck plunger — the outdoor unit will not energize even when the thermostat is calling for cooling. Chattering, visible arc burns, or a system that runs continuously without shutting off are also common signs of contactor failure.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30-amp contact rating | Direct OEM replacement for part number HN51KC024 | Factory-matched electrical tolerances
  • OEM vs Generic: OEM contactors feature silver-alloy contacts rated for thousands of switching cycles. Generic contactors often use lower-grade contact material that pits and corrodes faster, leading to premature failure and potential compressor damage.
  • Install difficulty: 3/5 — Always shut off power at the disconnect box and confirm voltage is absent with a multimeter before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring before disconnecting terminals. High-voltage work — if unsure, consult a licensed HVAC technician.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.

Compatibility: Designed specifically for the Payne PA14NC024000AAAA 2-ton single-stage split-system air conditioner. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our parts specialists are available to confirm fitment — reach out before you buy for peace of mind.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA14NC024000AAAA?
Yes. This is the factory-specified OEM contactor for the Payne PA14NC024000AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA14NC024000AAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.