Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Payne 40A Contactor 2-Pole 24V Coil for PA13NR06000GBKAA
Payne

OEM Payne 40A Contactor 2-Pole 24V Coil for PA13NR06000GBKAA

SKU: PAYNE-PA13NR06000GBKAA-CONTACTOR-HN51JD026 Brand: Payne
Guaranteed to fit PA13NR06000GBKAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Payne 2-Pole Contactor 24V Coil for Model PA13NR06000GBKAA

This is the OEM factory-replacement contactor (part number HN51JD026) designed specifically for the Payne PA13NR06000GBKAA split-system air conditioner. The contactor is a high-voltage relay that receives a 24V signal from the thermostat and closes to send line voltage to the compressor and condenser fan motor. When the contactor fails — due to pitted or burned contacts, a stuck plunger, or a failed coil — the outdoor unit will not energize at all, even when the thermostat is calling for cooling. You may also notice the system humming without the compressor starting, or the unit running continuously without cycling off.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40 amp contact rating | Direct OEM replacement for part number HN51JD026 | Factory-matched contact material for full rated service life
  • OEM vs Generic: This OEM contactor meets Payne's exact coil pull-in voltage and contact resistance specifications. Aftermarket contactors frequently use thinner contact surfaces that pit and burn prematurely, leading to repeat failures within a single cooling season.
  • Install difficulty: 3/5 — Requires shutting off power at the disconnect and breaker before proceeding. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all high-voltage wiring connections before disconnecting. Capacitor discharge is recommended before working near electrical components.
  • Warranty: 1-year OEM factory warranty. Orders placed by 3PM local time ship same business day from our climate-controlled parts warehouse.

Compatibility: This contactor is factory-specified for the Payne PA13NR06000GBKAA split-system condenser. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our HVAC parts specialists are available to confirm fitment — contact us before you buy if you have any questions. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR06000GBKAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR06000GBKAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR06000GBKAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online