Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA13NR06000GACAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA13NR06000GACAA

SKU: PAYNE-PA13NR06000GACAA-CONTACTOR-HN51JD026 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor HN51JD026 for Model PA13NR06000GACAA

This is the OEM replacement contactor (part number HN51JD026) factory-specified for the Payne PA13NR06000GACAA split-system air conditioner. The contactor is a high-voltage relay that receives a 24V signal from the thermostat and closes to send 240V power to the compressor and condenser fan motor. When it fails, the most common symptoms are an air conditioner that won't turn on at all, a system that hums but never starts, or pitted/burned contacts that cause intermittent operation or tripped breakers.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40 amp contact rating | Direct OEM replacement matching factory fit and electrical specifications for the PA13NR06000GACAA
  • OEM vs Generic: This OEM contactor uses factory-grade contact material rated for thousands of switching cycles. Generic contactors frequently use lower-grade alloys that pit and arc prematurely, leading to repeat failures and potential compressor damage.
  • Install Difficulty: 3/5 — Always disconnect power at the disconnect box AND breaker before servicing. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removal. Capacitor discharge is recommended before working in the unit.
  • Warranty: 1-year OEM factory warranty included. Orders placed by 3PM EST ship same business day from our climate-controlled warehouse.

Compatibility: Engineered specifically for the Payne PA13NR06000GACAA single-stage split-system condenser. Verify your existing contactor's pole count and coil voltage against your unit's wiring diagram before ordering. Our HVAC parts specialists are available to confirm fitment — just reach out before you order and we'll make sure you get the right part the first time.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR06000GACAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR06000GACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR06000GACAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart