Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA13NR060000AHAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA13NR060000AHAA

SKU: PAYNE-PA13NR060000AHAA-CONTACTOR-HN51JD026 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor HN51JD026 for Model PA13NR060000AHAA

This is the factory OEM replacement contactor (part number HN51JD026) for the Payne PA13NR060000AHAA 5-ton split-system air conditioner. The contactor is a high-voltage relay controlled by the 24V signal from your thermostat — when the call for cooling arrives, the contactor closes and sends 240V power to both the compressor and condenser fan motor. A failed contactor is one of the most common reasons an AC unit will hum without starting, fail to energize entirely, or run continuously without shutting off due to welded contacts.

  • Specs: 2-pole configuration | 24V AC coil voltage | 40-amp rating | Direct OEM replacement — Part No. HN51JD026 | Factory-spec contact material for arc resistance and long service life
  • OEM vs Generic: This is the genuine OEM part built to Payne factory specifications. Generic contactors often use lower-grade contact materials that pit and weld prematurely, especially in high-cycle summer conditions — OEM ensures reliable pull-in voltage and rated ampacity over the life of the unit.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and verify voltage is absent with a multimeter before touching any wiring. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers. Photograph all wiring connections before removal. Line and load terminals must be correctly identified during reinstallation.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our stocked warehouse when ordered before cutoff.

Compatibility: Engineered specifically for the Payne PA13NR060000AHAA 5-ton single-stage split-system condenser. Cross-reference OEM part number HN51JD026 and confirm coil voltage and pole configuration on your unit's wiring diagram or data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — contact us anytime.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR060000AHAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR060000AHAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR060000AHAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.