OEM Payne 2-Pole Contactor HN51JD026 for Model PA13NR060000AEAA

This is the factory OEM replacement contactor (part number HN51JD026) for the Payne PA13NR060000AEAA 5-ton split-system air conditioner. The contactor is a high-voltage relay that receives a 24V signal from the thermostat and closes to send 240V power to the compressor and condenser fan motor. When a contactor fails, the most common symptoms are an AC unit that won't turn on at all, a compressor that hums but doesn't start, or pitted/burned contacts that cause intermittent operation and excessive power draw.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30-amp rating | Direct OEM replacement for part number HN51JD026 | Factory-spec contact material for full rated service life
  • OEM vs Generic: This OEM contactor uses factory-specified contact alloy and coil wire gauge. Generic contactors frequently feature undersized contacts that pit and weld prematurely under the high inrush current of a 5-ton compressor, leading to repeat failures within a single season.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and verify zero voltage with a multimeter before touching any wiring. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removal. Swap wires one at a time to prevent miswiring.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Orders placed before 3 PM EST ship same business day from our climate-controlled warehouse.

Compatibility: Designed and factory-specified for the Payne PA13NR060000AEAA 5-ton single-stage R-410A split-system condenser. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you buy — no guesswork required.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR060000AEAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR060000AEAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR060000AEAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart