Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA13NR060000ACAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA13NR060000ACAA

SKU: PAYNE-PA13NR060000ACAA-CONTACTOR-HN51JD026 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor (HN51JD026) for Model PA13NR060000ACAA

This is the factory OEM replacement contactor for the Payne PA13NR060000ACAA split-system air conditioner. The contactor acts as the high-voltage relay that connects utility power to both the compressor and condenser fan motor when the thermostat sends a 24V signal. When the contactor fails — through worn contacts, pitted surfaces, or a burned-out coil — the outdoor unit will fail to energize entirely, leaving your system blowing warm air or not responding at all. OEM part number HN51JD026 is the exact factory-specified replacement, ensuring correct coil voltage, contact rating, and terminal layout.

  • Specs: 2-pole configuration | 24V AC coil voltage | Heavy-duty contact rating matched to 5-ton (060) unit load | Factory-matched terminal layout for direct swap
  • OEM vs Generic: OEM contactors use silver-alloy contact tips rated for thousands of switching cycles. Generic contactors often use lower-grade alloys that pit and weld prematurely, causing callbacks and repeat failures — especially on high-demand 5-ton units like the PA13NR060000ACAA.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and wait for capacitors to discharge before beginning work. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, a multimeter for coil continuity verification. Photograph all wiring before disconnecting terminals.
  • Warranty: 1-year OEM factory warranty. Orders placed before cutoff ship the same business day from our stocked warehouse.

Compatibility: Designed specifically for the Payne PA13NR060000ACAA 5-ton single-stage split-system condenser. Always confirm your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our parts specialists are available to verify fitment — order with confidence and get your system back up and running fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR060000ACAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR060000ACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR060000ACAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart