Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA13NR04800GADAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA13NR04800GADAA

SKU: PAYNE-PA13NR04800GADAA-CONTACTOR-HN51KC024 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor 24V Coil for Model PA13NR04800GADAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Payne PA13NR04800GADAA split-system air conditioner. The contactor is a high-voltage relay that receives a 24V signal from the thermostat and closes to deliver 240V power to the compressor and condenser fan motor. When the contactor fails — due to pitted or burned contacts, a worn coil, or contacts stuck open or closed — the system will either fail to start entirely, run continuously without shutting off, or trip the breaker repeatedly.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40 amp contact rating | Direct OEM replacement per part number HN51KC024 | Factory-matched coil pull-in voltage for reliable switching
  • OEM vs Generic: This OEM contactor uses factory-spec contact material and coil windings. Generic contactors often use lower-grade contact alloys that pit and burn faster under the repeated high-current switching demands of a residential condenser — shortening service life significantly in high-cycle climates.
  • Install difficulty: 3/5 — Always shut off power at both the disconnect box and the breaker before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, a multimeter to verify de-energization, and wire labels or a phone camera to document terminal connections before removal. Exercise extreme caution — capacitor terminals nearby may still hold a lethal charge even with power off.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed by cutoff time ship same business day from our warehouse.

Compatibility: Engineered specifically for the Payne PA13NR04800GADAA 4-ton single-stage R-410A split-system condenser. Always confirm the coil voltage and pole configuration on your unit's data plate before ordering. Our parts specialists are available to verify fitment — your system runs right or we make it right.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR04800GADAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR04800GADAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR04800GADAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.