OEM Payne 2-Pole Contactor 24V Coil for Model PA13NR03000GBLAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Payne PA13NR03000GBLAA split-system air conditioner. The contactor is a high-voltage relay that receives a 24V signal from your thermostat and closes the circuit to send 240V power to your compressor and condenser fan motor. When the contactor fails — due to pitted or burned contacts, a stuck plunger, or a failed coil — your outdoor unit will either refuse to start entirely, short-cycle, or run continuously without cycling off. Replacing a worn contactor is one of the most cost-effective repairs you can make to restore full system operation.

  • Specs: 2-pole configuration | 24V coil voltage | Rated for single-stage cooling systems | Factory-matched to Payne PA13NR03000GBLAA electrical specifications
  • OEM vs Generic: OEM contactors like this HN51KC024 feature precisely rated contact surfaces and coil windings that meet factory standards. Generic contactors may use thinner contact material that pits faster under load, leading to premature failure and potential compressor damage.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box and breaker panel before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wire connections before removing the old contactor. Wires must be transferred one at a time to avoid miswiring.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed by 3 PM ship same business day from our climate-controlled warehouse.

Compatibility: Designed specifically for the Payne PA13NR03000GBLAA split-system condenser. Always verify coil voltage and pole configuration on your unit's data plate before ordering. Not sure about fitment? Our HVAC parts specialists are available to confirm compatibility before you purchase — no guesswork required.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR03000GBLAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR03000GBLAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR03000GBLAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.