OEM Payne 2-Pole Contactor 24V Coil for Model PA13NR03000GAEAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Payne PA13NR03000GAEAA split-system air conditioner. The contactor is a high-voltage relay that receives a 24V signal from the thermostat and closes the circuit to supply line voltage to the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a burned coil, or contacts welded shut — the system will either refuse to start entirely, run continuously without cycling off, or trip the breaker repeatedly. Replacing a worn contactor is one of the most common and cost-effective AC repairs a technician or experienced homeowner can perform.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30-amp rated contacts | Matches OEM factory specification for Payne PA13NR03000GAEAA
  • OEM vs Generic: OEM part HN51KC024 uses factory-grade silver-alloy contact tips rated for full service life. Generic contactors frequently use lower-grade contacts that pit faster under high-cycle conditions, risking premature failure and potential compressor damage.
  • Install difficulty: 2/5 — Always shut off power at the disconnect box and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old unit. Line voltage wires must be secured with proper terminals — do not leave exposed conductors.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our warehouse.

Compatibility: Designed specifically for the Payne PA13NR03000GAEAA condenser unit. Verify coil voltage and pole configuration on your unit's wiring diagram or data plate before ordering. Our parts specialists are available to confirm fitment — fast shipping means your system is back online without delay.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NR03000GAEAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NR03000GAEAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NR03000GAEAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.