Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Payne 40A Contactor 2-Pole 24V Coil for PA13NA0600NGAEAA
Payne

OEM Payne 40A Contactor 2-Pole 24V Coil for PA13NA0600NGAEAA

SKU: PAYNE-PA13NA0600NGAEAA-CONTACTOR-HN51JD026 Brand: Payne
Guaranteed to fit PA13NA0600NGAEAA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Payne 2-Pole Contactor HN51JD026 for Model PA13NA0600NGAEAA

This is the factory OEM replacement contactor (part number HN51JD026) for the Payne PA13NA0600NGAEAA split-system air conditioner. The contactor is a high-voltage relay that receives a 24V signal from your thermostat and closes the circuit to send 240V power to the compressor and condenser fan motor. When the contactor fails, symptoms include the outdoor unit not turning on at all, the compressor humming but not starting, or the system running continuously without shutting off due to welded contacts.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40 amp rating | Factory-matched contact material and coil resistance for reliable switching
  • OEM vs Generic: This OEM contactor uses factory-spec contact alloy and coil windings, ensuring proper pull-in voltage and contact longevity. Generic contactors often use inferior contact material that pits and welds prematurely under high-cycle summer loads, leading to repeat failures.
  • Install difficulty: 3/5 — Requires shutting off the disconnect and verifying zero voltage with a multimeter before touching any terminals. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, non-contact voltage tester. Photograph all wiring before disconnecting and replace one wire at a time.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed specifically for the Payne PA13NA0600NGAEAA 5-ton single-stage R-410A split-system condenser. Verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Not sure if this is the right part? Our HVAC parts specialists verify fitment before you buy — contact us before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NA0600NGAEAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NA0600NGAEAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NA0600NGAEAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.