Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA13NA04800GABAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA13NA04800GABAA

SKU: PAYNE-PA13NA04800GABAA-CONTACTOR-HN51KC024 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor 24V Coil for Model PA13NA04800GABAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Payne PA13NA04800GABAA split-system air conditioner. The contactor acts as the high-voltage relay that connects line-voltage power to the compressor and condenser fan motor when your thermostat calls for cooling. When the contactor fails — due to pitted or burned contacts, a stuck plunger, or a failed coil — the outdoor unit will not start despite the thermostat signaling for operation. You may hear a clicking or buzzing from the contactor with no compressor response.

  • Specs: 2-pole configuration | 24V control coil | Rated for single-phase operation | OEM part number HN51KC024 | Factory-matched contact rating for 4-ton R-22 condensing unit
  • OEM vs Generic: This is a genuine OEM contactor built to Payne factory specifications. Generic contactors may use lower-grade contact materials that arc and pit more quickly, leading to premature failure — especially in high-cycle summer conditions. OEM ensures correct coil pull-in voltage and contact longevity.
  • Install difficulty: 2/5 — Always shut off power at both the disconnect and the breaker before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor. Wire-for-wire replacement takes most technicians under 20 minutes.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Designed specifically for the Payne PA13NA04800GABAA 4-ton single-stage split-system condenser. Verify OEM part number HN51KC024 on your existing contactor's label or unit wiring diagram before ordering. Our parts specialists are available to confirm fitment prior to purchase — don't hesitate to reach out. Order today and get same-day shipping on all in-stock OEM parts.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA13NA04800GABAA?
Yes. This is the factory-specified OEM contactor for the Payne PA13NA04800GABAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA13NA04800GABAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.