Same-day shipping on orders before 3PM CST · 15,000+ OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Payne Contactor 2-Pole 24V Coil f...
OEM Payne Contactor 2-Pole 24V Coil for PA12NA036000ACAA
Payne

OEM Payne Contactor 2-Pole 24V Coil for PA12NA036000ACAA

SKU: PAYNE-PA12NA036000ACAA-CONTACTOR-HN51KC024 Brand: Payne

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Payne 2-Pole Contactor HN51KC024 for Model PA12NA036000ACAA

This OEM contactor (part number HN51KC024) is the factory-specified replacement for the Payne PA12NA036000ACAA split-system air conditioner. The contactor is a high-voltage relay controlled by a 24V signal from your thermostat — when the thermostat calls for cooling, the contactor closes and sends line voltage to the compressor and condenser fan motor. When it fails, the most common symptoms are an AC unit that won't turn on at all, a compressor that runs continuously without cycling off, or visible pitting and burning on the contact points inside the unit.

  • Specs: 2-pole configuration | 24V AC coil voltage | 30–40 amp rated | Direct OEM replacement for part number HN51KC024 | Factory-matched contact surface material for long service life
  • OEM vs Generic: This is a genuine OEM contactor built to Payne's exact electrical specifications. Generic contactors may use lower-grade contact alloys that pit and burn more rapidly, leading to premature failure and potential compressor damage.
  • Install Difficulty: 3/5 — Always shut off power at both the disconnect box and breaker panel before beginning work. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, wire labels or tape. Photograph all wiring connections before disconnecting. Line-voltage terminals remain energized until the disconnect is pulled — treat all wires as live until confirmed otherwise.
  • Warranty: 1-year OEM factory warranty included. In-stock and ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed specifically for the Payne PA12NA036000ACAA 3-ton split-system condenser. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. If you have any fitment questions, our HVAC parts specialists are available to confirm compatibility before you purchase — we want to make sure you get the right part the first time.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Payne PA12NA036000ACAA?
Yes. This is the factory-specified OEM contactor for the Payne PA12NA036000ACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Payne PA12NA036000ACAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Payne parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Payne contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.