Genuine OEM ICP motor(psn 2712uxxxxx), part HD60FK651 — the factory-exact replacement for the 40RUAA14A. Fitment guaranteed — free returns if it doesn't fit.
| Hp | 3 |
| Voltage | 208-230/460 |
| Rpm | 1725 |
| Poles | 4 |
| Mtype | induction, belt-drive (NOT ECM) |
| Note | SCOPE: 3-phase belt-drive induction blower motor, not ECM. Nameplate 3HP per Carrier Enterprise & Peirce; NorthStock/PartsTown list 3.7HP (service-factor rating). Prefix prior of '5HP' is incorrect for this PN (5HP is sibling HD60FK652). |
| OEM Part Number | HD60FK651 |
| Brand | ICP |
| Condition | New — genuine OEM |
Watch for: The blower hums but won't turn, squealing or grinding from the housing, weak airflow at the registers. Catching it early protects the components around it.
Kill power and note the rotation arrow and wiring colors before removal. Transfer the mounting bracket, set the shaft set-screw against the flat, and match the capacitor rating if one is used. Restore power and run a full cycle, checking for vibration and confirming amp draw against the nameplate.
Is this the exact OEM part for my 40RUAA14A? Yes — verified factory fitment for that model.
Not sure of your model? Chat with Mike with the number from your unit's nameplate and we'll confirm before you order.