OEM Carrier Furnace Transformer 40VA 120V to 24V for Model UPFLOW070US12B

The Carrier HT01CN001 is the factory-specified OEM control transformer for the Carrier UPFLOW070US12B upflow gas furnace. This transformer steps down 120V line voltage to a 12/24V low-voltage output at 40VA, powering the furnace's entire control circuit — including the thermostat, control board, ignition sequence, and safety safeties. When this transformer fails, the furnace loses its low-voltage control circuit entirely: the thermostat goes dark, the system will not respond to any call for heat or cooling, and in some cases you may detect buzzing, burning smell, or a tripped inline fuse. Replacing it with the correct OEM unit restores the factory-spec voltage and ensures all downstream controls operate within design parameters.

  • Specs: 120V primary | 12V & 24V secondary outputs | 40VA rated | Factory-matched OEM tolerances | Part No. HT01CN001 (supersedes HT01BJ115, 19EA41612, 19EA42612)
  • OEM vs Generic: OEM transformers are wound and insulated to Carrier's exact VA and voltage tolerances. Undersized or off-tolerance aftermarket units can over-stress the secondary circuit, cause nuisance fuse trips, and void equipment warranties.
  • Install Difficulty: 3/5 — Requires shutting off power at the disconnect AND the breaker before accessing the transformer. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter (to verify 24V output post-install). Photograph all low-voltage wiring connections before removal. The inline fuse on the 24V circuit should be inspected and replaced if blown — a failed fuse is often the root-cause symptom.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse on orders placed before cutoff.

Compatibility: Engineered as a direct OEM drop-in replacement for the Carrier UPFLOW070US12B upflow gas furnace. Verify your existing transformer's primary voltage (120V), secondary voltage (24V), and VA rating (40VA) on the data plate before ordering. If your furnace's inline fuse is blown, inspect all low-voltage wiring for shorts before installing the new transformer to prevent immediate failure. Questions about fitment? Our HVAC parts specialists confirm compatibility before you order — no guesswork.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Carrier OEM Carrier Furnace Transformer 40VA 120V/24V — UPFLOW070US12B?
Yes. This is the factory-specified OEM transformer for the Carrier OEM Carrier Furnace Transformer 40VA 120V/24V — UPFLOW070US12B. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Carrier OEM Carrier Furnace Transformer 40VA 120V/24V — UPFLOW070US12B?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online