OEM Carrier 3-Pole Contactor Kit HN660017 for Model TJACCYCRLOWAMB001A01

This OEM contactor kit (part number HN660017) is the factory-authorized replacement for Carrier TJACCYCRLOWAMB001A01 low-ambient air conditioning systems. Manufactured by Tyco Electronics (model 3100-30Q828WA), this 3-pole contactor is the high-voltage switching relay that connects and disconnects line voltage to the compressor and condenser fan motor every time the thermostat calls for cooling. When the contactor fails, symptoms include the outdoor unit failing to energize, audible chattering or humming at the unit, pitted or welded contact points, or the system running continuously and refusing to shut off.

  • Specs: 3-pole configuration | 24V AC coil | Tyco Electronics model 3100-30Q828WA | Factory Authorized Parts (FAP) | Cross-reference: HN53TB024
  • OEM vs Generic: This is a Factory Authorized Part meeting Carrier's exact electrical tolerances. Generic contactors often use thinner contact materials, leading to faster pitting and premature failure — especially in low-ambient cycling applications.
  • Install difficulty: 3/5 — Always shut off all power at the disconnect box before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, and electrical tape. Photograph all wiring terminations before disconnecting the old unit to ensure accurate reinstallation.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered by cutoff time.

Compatibility: Designed for Carrier model TJACCYCRLOWAMB001A01 low-ambient condensing systems. Verify pole count, coil voltage, and amperage ratings on your unit's data plate prior to ordering. Our parts specialists are available to confirm fitment — contact us before you order if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier TJACCYCRLOWAMB001A01?
Yes. This is the factory-specified OEM contactor for the Carrier TJACCYCRLOWAMB001A01. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier TJACCYCRLOWAMB001A01?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.