Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008
OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008
OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008
OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008
Carrier

OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008

SKU: CARRIE-TJACCYCRECOMZR008C00-CONTROL_BOARD-HH63AW001 Brand: Carrier
Guaranteed to fit TJACCYCRECOMZR008 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Economizer Control Board Kit HH63AW001 for Model TJACCYCRECOMZR008C00

This is the factory OEM replacement Economizer Control Board Kit (Part No. HH63AW001) engineered specifically for the Carrier TJACCYCRECOMZR008C00 commercial rooftop unit. The economizer control board manages the automated outside-air damper sequencing, free-cooling logic, demand-controlled ventilation signals, and fault diagnostics for your unit's economizer assembly. When this board fails, you may experience erratic damper behavior, a damper stuck fully open or closed, free-cooling lockout, fault codes on the unit controller, or a complete loss of economizer function — all of which directly impact energy efficiency, occupant comfort, and code compliance.

  • Specs: OEM Kit Part No. HH63AW001 | Factory-matched control logic for Carrier TJACCYCRECOMZR008C00 | Includes board and required mounting/wiring hardware | 24V control circuit compatible
  • OEM vs Generic: This is a genuine Carrier OEM board — not an aftermarket substitute. OEM boards carry factory-programmed firmware and calibrated sensor thresholds. Generic boards risk mis-sequencing damper travel, triggering nuisance faults, or voiding unit warranties.
  • Install Difficulty: 3/5 — Recommended for qualified HVAC technicians. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, and laptop/tablet for any required controller re-pairing. Always de-energize the unit at the disconnect before servicing. Photograph all wiring harness connections prior to removal.
  • Warranty: 1-year OEM factory warranty against defects. In-stock units ship same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Designed and factory-specified for the Carrier TJACCYCRECOMZR008C00 commercial packaged rooftop unit economizer assembly. Always cross-reference the part number on your existing board's label and your unit's wiring diagram before ordering. Our HVAC parts specialists are available to verify fitment — contact us before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Circuit Board fit my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008?
Yes. This is the factory-specified OEM circuit board for the Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the circuit board on my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TJACCYCRECOMZR008?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this circuit board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier circuit board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online