Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier LP Gas Pressure Switch HK02LB008 — TFACCYCRLPELEV002A00
Carrier

OEM Carrier LP Gas Pressure Switch HK02LB008 — TFACCYCRLPELEV002A00

SKU: CARRIE-TFACCYCRLPELEV002A00-PRESSURE_SWITCH-HK02LB008 Brand: Carrier
Guaranteed to fit TFACCYCRLPELEV002A00 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier LP Gas Pressure Switch HK02LB008 for Model TFACCYCRLPELEV002A00

This is the genuine OEM Carrier LP (propane) gas pressure switch, part number HK02LB008, factory-specified for the Carrier TFACCYCRLPELEV002A00. The gas pressure switch monitors incoming LP gas supply pressure and interrupts the ignition sequence if pressure falls outside the safe operating range. When this switch fails or drifts out of calibration, the furnace will typically lock out on a pressure fault — resulting in a no-heat call, a flashing fault code, or a system that ignites briefly and then shuts down. Replacing it with the correct OEM part ensures the unit operates within factory-specified safety parameters.

  • Specs: LP (propane) gas pressure switch | Cut-out pressure: 6.5 in. w.c. | Factory-calibrated | Direct OEM replacement for Carrier/Bryant applications
  • OEM vs Generic: OEM switches are pre-set to exact factory cut-out pressure tolerances. Aftermarket alternatives may carry wider calibration variances that can cause nuisance lockouts or, worse, allow operation outside safe LP pressure ranges.
  • Install difficulty: 2/5 — Shut off gas supply and power before servicing. Tools needed: 1/4" nut driver, needle-nose pliers, and tubing to transfer pressure tap connections. Always confirm replacement cut-out pressure matches your unit's data plate before reinstalling.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered by 3 PM local time.

Compatibility: Designed for Carrier model TFACCYCRLPELEV002A00 LP gas furnace applications. Note: HK02LB008 has been discontinued by the manufacturer; HK02MB008 is the OEM-approved direct replacement and ships in its place where stock is exhausted. Verify your unit's gas type (LP/propane) and pressure switch cut-out rating on the data plate before ordering. Our fitment team is available to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier LP Gas Pressure Switch HK02LB008 — TFACCYCRLPELEV002A00?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier LP Gas Pressure Switch HK02LB008 — TFACCYCRLPELEV002A00. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier LP Gas Pressure Switch HK02LB008 — TFACCYCRLPELEV002A00?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online