Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427
OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427
OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427
OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427
Carrier

OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427

SKU: CARRIE-TFACCY50DK480427-PRESSURE_SWITCH-HK02ZA442 Brand: Carrier
Guaranteed to fit TFACCY50DK480427 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch 448/327# for Model TFACCY50DK480427

This genuine OEM Carrier high pressure switch (part #HK02ZA442) is the factory-specified replacement for the Carrier TFACCY50DK480427 packaged unit. The high pressure switch continuously monitors refrigerant-side pressure and opens the circuit when system pressure exceeds safe operating limits. When this switch fails or trips, the system may experience nuisance lockouts, short-cycling, or a complete no-cooling condition — even when refrigerant charge and airflow are normal. A faulty switch that won't reset is a clear sign it's time to replace.

  • Specs: Opening pressure: 448 PSI | Closing (reset) pressure: 327 PSI | Operating voltage: 240V | OEM Part #: HK02ZA442 | Replaces: HK02ZA439
  • OEM vs Generic: This is a genuine Carrier factory-authorized part with exact pressure calibration. Aftermarket switches often carry wider tolerances, risking premature trips or, worse, failure to open — putting compressors and system components at risk.
  • Install difficulty: 2/5 — Always recover refrigerant per EPA Section 608 before disconnecting the switch. Tools needed: refrigerant recovery unit, manifold gauge set, adjustable wrench, multimeter. Verify the circuit is de-energized before handling. Photograph wiring before disconnecting.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier TFACCY50DK480427 packaged HVAC unit. Cross-references with internal switch code 448-327# and replaces superseded part number HK02ZA439. Always verify your unit's nameplate pressure ratings before ordering. Our team is available to confirm fitment — contact us before you order if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier High Pressure Switch 448/327# — TFACCY50DK480427?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.