Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier High Pressure Switch 448/327 PSI for TFACCY50DK480415
Carrier

OEM Carrier High Pressure Switch 448/327 PSI for TFACCY50DK480415

SKU: CARRIE-TFACCY50DK480415-PRESSURE_SWITCH-HK02ZA442 Brand: Carrier
Guaranteed to fit TFACCY50DK480415 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier High Pressure Switch 448/327 PSI for Model TFACCY50DK480415

This is the genuine OEM Carrier high pressure switch (part number HK02ZA442), factory-specified for the Carrier TFACCY50DK480415 commercial packaged unit. The high pressure switch is a critical refrigerant-circuit safety device that monitors refrigerant pressure on the high side of the system. When discharge pressure exceeds the safe threshold, the switch opens the control circuit and shuts the system down to prevent compressor damage, refrigerant leaks, or catastrophic equipment failure. When the high pressure switch fails or trips, you'll typically see symptoms such as nuisance high-pressure lockouts, an unresponsive compressor, or a system that short-cycles and won't hold a call for cooling.

  • Specs: Opens at 448 PSI | Closes at 327 PSI | High-pressure refrigerant-circuit safety switch | Replaces superseded part HK02ZA439
  • OEM vs Generic: This is a genuine Carrier factory part engineered to exact pressure setpoints. Aftermarket substitutes often carry wider tolerances, risking false trips or — more dangerously — late shutdowns that allow damaging over-pressure conditions.
  • Install difficulty: 3/5 — Refrigerant-side work. A licensed HVAC technician should perform this repair. The system must be recovered before accessing the high-side port. Tools needed: manifold gauge set, recovery machine, refrigerant scale, adjustable wrench, multimeter for continuity verification post-install.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier TFACCY50DK480415 commercial packaged unit. Verify your unit's data plate and existing switch PSI ratings before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — contact us anytime.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier TFACCY50DK480415?
Yes. This is the factory-specified OEM pressure switch for the Carrier TFACCY50DK480415. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier TFACCY50DK480415?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online