Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Economizer Control Board Kit HH63AW001 — TFACCY48TM480100
Carrier

OEM Carrier Economizer Control Board Kit HH63AW001 — TFACCY48TM480100

SKU: CARRIE-TFACCY48TM480100-CONTROL_BOARD-HH63AW001 Brand: Carrier
Guaranteed to fit TFACCY48TM480100 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier DCV Economizer Control Board Kit HH63AW001 for Model TFACCY48TM480100

This is the genuine OEM factory-replacement Economizer Control Board Kit (HH63AW001) for the Carrier TFACCY48TM480100 commercial packaged rooftop unit. The economizer control board is the brain of the economizer subsystem — it continuously monitors outdoor air conditions, interprets demand-controlled ventilation (DCV) signals, and commands the damper actuator to bring in the precise amount of fresh outside air needed to satisfy both indoor air quality (IAQ) and energy efficiency requirements. When this board fails, symptoms typically include a stuck-open or stuck-closed damper, loss of DCV response, fault codes on the unit controller, or complete economizer lockout — all of which can trigger building code compliance issues and spike energy costs on commercial rooftop installations.

  • OEM Part Number: HH63AW001 | Cross-Reference: W7212A1017 | Factory Authorized Carrier Replacement Components Division part
  • Specs: 120V input | 60 Hz | All inputs Class 2 rated | Dimensions approx. 4" × 4" × 2" | Weight: 1 lb | Designed for DCV (Demand-Controlled Ventilation) economizer systems on Carrier commercial RTU platforms
  • OEM vs Generic: OEM boards are programmed with Carrier-specific firmware and factory-calibrated sensor thresholds. Third-party substitutes frequently lack DCV compatibility, cause damper hunting, or trigger false fault codes — leaving your rooftop unit non-compliant and your warranty void.
  • Install Difficulty: 3/5 — This is a commercial rooftop board replacement. Tools required: insulated screwdrivers, multimeter, low-voltage wire labels, and access to unit wiring diagram. De-energize the unit fully before opening the economizer compartment. Document all wiring connections with photographs before disconnecting. Allow 10–15 minutes for the new board to initialize on first power-up.
  • Warranty: 1-year OEM factory warranty through Carrier. Ships same business day from our warehouse in original Carrier Factory Authorized Parts packaging.

Compatibility: Engineered for the Carrier TFACCY48TM480100 commercial packaged rooftop unit. Also fits Bryant and Payne models that share the HH63AW001 / W7212A1017 economizer board specification — verify your unit's wiring diagram and existing board part number before ordering. Have questions about fitment? Our HVAC parts specialists verify compatibility before you buy — contact us today and ships same day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TFACCY48TM480100?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TFACCY48TM480100. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TFACCY48TM480100?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online