Same-day shipping on orders before 3PM CST · 10,893 OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart
Home / OEM Carrier Pressure Switch 7#OPN 22#...
OEM Carrier Pressure Switch 7#OPN 22#CLS 50
Carrier

OEM Carrier Pressure Switch 7#OPN 22#CLS 50" Leads — TFACCY389026201

SKU: CARRIE-TFACCY389026201-PRESSURE_SWITCH-HK02ZB038 Brand: Carrier

Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

OEM Carrier Pressure Switch HK02ZB038 — 7#OPN / 22#CLS / 50" Leads for TFACCY389026201

This is the factory OEM replacement pressure switch (part number HK02ZB038) for the Carrier TFACCY389026201. The pressure switch is a safety device that proves the inducer blower is operating and generating adequate negative pressure before allowing the gas valve and ignition sequence to begin. When this switch fails or sticks, the furnace will attempt to start, fail to advance past the inducer pre-purge stage, and ultimately lock out — leaving you with no heat. Common symptoms include an inducer motor that runs but the furnace never lights, a flashing fault code indicating a pressure switch error, or a unit that starts and immediately shuts back down.

  • Specs: 7 PSI open | 22 PSI close | 50" wire leads | OEM-matched W.C. rating | Factory-specified Carrier replacement
  • OEM vs Generic: OEM pressure switches are factory-calibrated to exact set-point tolerances. Aftermarket alternatives can drift out of specification, causing nuisance lockouts or — worse — failing to protect the heat exchanger from unsafe draft conditions.
  • Install difficulty: 2/5 — Turn off power and gas before beginning. Tools needed: flathead screwdriver, needle-nose pliers. Note the hose port orientation and lead routing before disconnecting. Reconnect the rubber tubing fully to avoid false trips after installation.
  • Warranty: 1-year OEM factory warranty against manufacturing defects. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered and factory-matched for the Carrier TFACCY389026201. Always confirm the pressure switch W.C. rating printed on your existing switch label matches before installing. Have a question about fitment? Our HVAC parts specialists verify compatibility before you order — call or chat now.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email support@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days
Home Shop Search Account Cart