OEM Carrier DCV Economizer Control Board Kit HH63AW001 for Model TCHC1850HE403359

This is a genuine OEM Carrier Factory Authorized Part — the HH63AW001 DCV Economizer Control Board Kit — designed as the direct factory replacement for the Carrier TCHC1850HE403359 commercial rooftop unit. The economizer control board is the command center of your unit's free-cooling strategy: it continuously monitors outdoor air quality and enthalpy conditions, modulates the damper actuator, and manages the blend of outdoor and recirculated air to minimize mechanical cooling loads. When this board fails, you'll typically see symptoms such as the economizer damper stuck open or closed, loss of demand-controlled ventilation (DCV) response, fault codes on the unit controller, erratic damper hunting, or a complete loss of free-cooling — all of which drive up energy costs and compromise indoor air quality in commercial spaces.

  • Specs: OEM Part# HH63AW001 | Cross-reference: W7212A1017 | Input voltage: 120V / 60Hz | Dimensions: approx. 4" × 4" × 2" | Weight: 1 lb | All inputs Class 2 | Factory Authorized Parts — Carrier Corporation
  • OEM vs Generic: This is a genuine Carrier OEM board — not a third-party clone. OEM boards are pre-programmed with the correct control logic, damper calibration parameters, and safety thresholds for your unit. Aftermarket substitutes may lack DCV firmware compatibility, leading to improper damper modulation and potential building code non-compliance.
  • Install difficulty: 3/5 — Shut off all power and lockout/tagout before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, phone/camera for wiring documentation. Label and photograph all harness connectors before removal. Recalibrate the damper actuator after board replacement per the unit service manual. Recommended for qualified HVAC technicians.
  • Warranty: 1-year OEM factory warranty against defects. Ships same business day from our warehouse. Note: Electrical control boards are non-returnable once installed — verify part number against your unit's data plate before ordering.

Compatibility: Designed for the Carrier TCHC1850HE403359 commercial rooftop unit economizer assembly. Cross-references OEM part W7212A1017. Verify your existing board's part number on the component label before ordering. Our team is available to confirm fitment — contact us before you buy if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE403359?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE403359. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE403359?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.