Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE400984
Carrier

OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE400984

SKU: CARRIE-TCHC1850HE400984-CONTROL_BOARD-HH63AW001 Brand: Carrier
Guaranteed to fit TCHC1850HE400984 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier DCV Economizer Control Board Kit HH63AW001 for Model TCHC1850HE400984

This is a genuine OEM Carrier Factory Authorized Part — the DCV Economizer Control Board Kit (part# HH63AW001) — designed as a direct, factory-matched replacement for the Carrier TCHC1850HE400984 commercial rooftop unit. The economizer control board is the intelligence center of your unit's economizer system: it continuously monitors outdoor and return-air conditions, modulates the outdoor air damper to maximize free cooling, and enforces demand-controlled ventilation (DCV) to maintain indoor air quality while minimizing mechanical cooling loads. When this board fails, common symptoms include a stuck-open or stuck-closed damper, inability to enter economizer mode, erratic outdoor air percentages, fault codes on the unit controller, or a complete economizer lockout that forces full mechanical cooling — driving up energy costs and reducing occupant comfort.

  • OEM Part Number: HH63AW001 | Cross-reference: W7212A1017 | Factory Authorized Parts — Carrier Corporation
  • Specs: Input voltage 120V | 60 Hz | All inputs Class 2 | Dimensions approx. 4.7" L × 3.2" W | Weight: 1 lb | Compatible with DCV (CO₂-based demand-controlled ventilation) economizer assemblies
  • OEM vs Generic: This is a genuine Carrier OEM board — not an aftermarket clone. OEM boards carry factory firmware, correct I/O logic for your specific RTU platform, and validated sensor thresholds. Aftermarket boards may use incompatible firmware or miscalibrated analog inputs that cause phantom fault codes or damper over-travel.
  • Install Difficulty: 3/5 — Requires disconnection of 24V and Class 2 low-voltage wiring harnesses plus the damper actuator link. Always de-energize the unit at the disconnect before servicing. Recommended tools: #2 Phillips and flathead screwdrivers, needle-nose pliers, multimeter, wiring camera/phone for photo documentation. A qualified HVAC technician is strongly recommended for this repair.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Engineered for the Carrier TCHC1850HE400984 commercial rooftop unit economizer assembly. Also cross-references to Bryant and Payne commercial RTU platforms using the W7212A1017 control. Verify your existing board's part number label before ordering — our parts specialists are available to confirm fitment at no charge. Order today and ship today — in stock and ready to go.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE400984?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE400984. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — TCHC1850HE400984?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online