OEM Carrier LP Gas Pressure Switch 6.5
Carrier

OEM Carrier LP Gas Pressure Switch 6.5" W.C. — TCACCYCRLPKIT9001A00

SKU: CARRIE-TCACCYCRLPKIT9001A00-PRESSURE_SWITCH-HK02LB008 Brand: Carrier
Guaranteed to fit TCACCYCRLPKIT9001A00 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier LP Gas Pressure Switch (HK02LB008) for Model TCACCYCRLPKIT9001A00

This OEM LP gas pressure switch is the factory-specified replacement part for the Carrier TCACCYCRLPKIT9001A00 propane (LP) gas system. The pressure switch monitors gas supply pressure and signals the control board to allow or interrupt the ignition sequence based on detected pressure levels. When this switch fails or drifts out of calibration, the unit will typically lock out before ignition, refuse to fire on a call for heat, or cycle off unexpectedly — leaving you with no heat on the coldest days.

  • Specs: LP (propane) gas pressure switch | 6.5" W.C. cut-out pressure setting | OEM part number HK02LB008 | Cross-reference: GFS3451-4036 | Factory-calibrated — no field adjustment required
  • OEM vs Generic: This is a genuine Carrier factory-authorized part, manufactured to exact pressure tolerances. Aftermarket substitutes may carry ±10–15% pressure variance, risking nuisance lockouts or unsafe gas flow conditions — especially critical on LP systems where pressure regulation is tighter than natural gas.
  • Install difficulty: 3/5 — Turn off gas supply and power before servicing. Tools needed: 1/4" nut driver, flat-head screwdriver, manometer (recommended for LP verification), and needle-nose pliers for hose barb connections. Always verify inlet gas pressure at the manifold after installation.
  • Warranty & Shipping: 1-year OEM manufacturer warranty. In stock and ships same business day from our warehouse. Note: HK02LB008 is the current OEM part; direct replacement cross-reference is HK02MB008 where noted.

Compatibility: Designed for the Carrier TCACCYCRLPKIT9001A00 LP (propane) gas system kit. Verify your unit's gas type (LP vs. natural gas) and the original pressure switch W.C. rating on your data plate before ordering — LP and natural gas pressure switches are not interchangeable. Our fitment team is available to confirm compatibility before you purchase.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier LP Gas Pressure Switch 6.5" W.C. — TCACCYCRLPKIT9001A00?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier LP Gas Pressure Switch 6.5" W.C. — TCACCYCRLPKIT9001A00. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier LP Gas Pressure Switch 6.5" W.C. — TCACCYCRLPKIT9001A00?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online