Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier LP Gas Pressure Switch HK02LB008 — SPACCYCPLPCONV009A00
Carrier

OEM Carrier LP Gas Pressure Switch HK02LB008 — SPACCYCPLPCONV009A00

SKU: CARRIE-SPACCYCPLPCONV009A00-PRESSURE_SWITCH-HK02LB008 Brand: Carrier
Guaranteed to fit SPACCYCPLPCONV009A00 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier LP Gas Pressure Switch HK02LB008 for Model SPACCYCPLPCONV009A00

This is the genuine OEM Carrier LP (propane) gas pressure switch, part number HK02LB008, engineered as a direct factory replacement for the SPACCYCPLPCONV009A00 unit. The pressure switch serves a critical safety function: it monitors the gas supply pressure and signals the control board to allow or interrupt ignition sequences. When this switch fails, the furnace or heating system will typically enter a lockout condition — refusing to fire, cycling off before ignition, or throwing a fault code related to pressure sensing. A failed pressure switch is one of the most common causes of a no-heat call in LP-fueled systems.

  • Specs: LP (Liquefied Propane / Propane Gas) rated | Factory-calibrated set point | Spade terminal connections | OEM-matched switching action and pressure rating for SPACCYCPLPCONV009A00
  • OEM vs Generic: This is a genuine Carrier OEM part — not an aftermarket approximation. OEM pressure switches are factory-calibrated to exact water column (W.C.) specifications. Generic substitutes frequently drift off set point, causing nuisance lockouts or, worse, unsafe operation. Don't compromise on a safety-critical component.
  • Install Difficulty: 2/5 — Straightforward swap requiring a flathead or Phillips screwdriver, needle-nose pliers, and a camera phone to photograph tubing and wiring before removal. Always shut off gas supply and power to the unit before beginning. Hose connections must be leak-tested after installation.
  • Warranty: 1-year OEM manufacturer warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed for the Carrier SPACCYCPLPCONV009A00 LP conversion/propane configuration. Verify your unit's gas type (LP vs. natural gas) and confirm part number HK02LB008 on your existing switch or equipment documentation before ordering. Our fitment team is available to confirm compatibility before you buy — same-day shipping on all in-stock orders.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier OEM Carrier LP Gas Pressure Switch HK02LB008 — SPACCYCPLPCONV009A00?
Yes. This is the factory-specified OEM pressure switch for the Carrier OEM Carrier LP Gas Pressure Switch HK02LB008 — SPACCYCPLPCONV009A00. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier OEM Carrier LP Gas Pressure Switch HK02LB008 — SPACCYCPLPCONV009A00?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.