Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Economizer Control Board Kit HH63AW001 — SPACCYCPECOMZR012
Carrier

OEM Carrier Economizer Control Board Kit HH63AW001 — SPACCYCPECOMZR012

SKU: CARRIE-SPACCYCPECOMZR012A00-CONTROL_BOARD-HH63AW001 Brand: Carrier
Guaranteed to fit SPACCYCPECOMZR012 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier DCV Economizer Control Board Kit HH63AW001 for Model SPACCYCPECOMZR012A00

This is a genuine OEM Carrier factory-replacement DCV Economizer Control Board Kit (part# HH63AW001), designed as the direct drop-in replacement for the Carrier SPACCYCPECOMZR012A00 packaged rooftop unit. The economizer control board is the brain behind your unit's outdoor air management — it continuously monitors CO₂ levels, enthalpy, and outdoor air conditions to modulate the economizer damper and maximize free cooling while maintaining indoor air quality (IAQ) standards. When this board fails, you'll typically see symptoms such as the economizer damper stuck open or closed, CO₂/DCV sensor faults, loss of ventilation control, or the unit running on full mechanical cooling even when favorable outdoor conditions exist.

  • Part Specs: OEM Part# HH63AW001 | Cross-reference: W7212A1017 | Input voltage: 120V / 60Hz | Dimensions approx. 4" × 4" × 2" | Weight: 1 lb | All inputs Class 2 rated
  • OEM vs Generic: This is a factory-authorized Carrier OEM board — not an aftermarket clone. Generic boards may lack proper DCV sensor calibration and enthalpy logic, leading to recurring faults, failed inspections, or IAQ code violations. OEM ensures exact firmware and relay specifications for your unit.
  • Install Difficulty: 3/5 — Commercial rooftop work requires licensed HVAC technician access. Tools needed: 1/4" and 5/16" nut drivers, needle-nose pliers, voltmeter, and wiring labels. Photograph all terminal connections before disconnecting. Lock out / tag out (LOTO) the unit before beginning any board replacement.
  • Warranty: 1-year OEM manufacturer warranty. Ships same business day from our warehouse when ordered before 3PM local time.

Compatibility: Engineered specifically for the Carrier SPACCYCPECOMZR012A00 commercial packaged rooftop unit with factory DCV economizer. Cross-references Honeywell W7212A1017. Verify your existing board part number against HH63AW001 before ordering — our fitment team is available to confirm compatibility. Order now and ship today!

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — SPACCYCPECOMZR012?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — SPACCYCPECOMZR012. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Economizer Control Board Kit HH63AW001 — SPACCYCPECOMZR012?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online