This is the factory-authorized OEM draft inducer pressure switch for the Carrier PY4GPAB60115AA packaged unit. The pressure switch proves that the inducer motor has created adequate negative pressure in the heat exchanger flue before allowing the ignition sequence to begin. When this switch fails or gets stuck open, the control board interprets it as an unsafe venting condition and locks out the system — resulting in a no-heat call with the furnace never advancing past the inducer stage. OEM part number HK06WC061 has been superseded by HK06MB061, the current factory-authorized replacement at the same 0.18" water column rating and identical SPST configuration.
Compatibility: Directly fits the Carrier PY4GPAB60115AA packaged unit. Also compatible with a wide range of Carrier, Bryant, and Payne packaged and split-system models specifying a 0.18" W.C. SPST pressure switch — always verify the W.C. rating on your existing switch's label before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you buy.