This OEM Carrier draft inducer pressure switch is the factory-specified replacement for the Carrier PY4GPAB48115AA packaged unit. The pressure switch monitors negative pressure created by the inducer blower motor to confirm safe venting conditions before allowing the ignition sequence to proceed. When this switch fails or sticks, the control board cannot verify inducer operation and the system will lock out — typically presenting as a furnace that attempts to start but shuts down before the burners ever light. A fault code pointing to a pressure switch or inducer circuit is the most common diagnostic indicator.
Compatibility: Fits Carrier PY4GPAB48115AA packaged units. Note that OEM part number HK06WC061 has been superseded by HK06MB061 — both are included with this listing. Compatible across Bryant and Payne models sharing the same 0.18" W.C. pressure switch specification. Always verify W.C. rating on your unit's data plate or existing switch before ordering. Our HVAC specialists are available to confirm fitment prior to purchase.