This OEM Carrier draft inducer pressure switch is the factory-specified replacement for the Carrier PY4GPAB36090NA packaged unit. The pressure switch monitors negative pressure created by the inducer motor to confirm that combustion airflow is safe and sufficient before allowing the ignition sequence to proceed. When this switch fails or sticks open, the furnace will not advance past the inducer stage — resulting in a no-heat lockout condition with the inducer motor running continuously but no spark or gas delivery.
Compatibility: Designed for the Carrier PY4GPAB36090NA packaged unit. Also fits select Bryant and Payne models requiring a 0.18" W.C. normally-open draft pressure switch. Note that OEM part HK06WC061 has been superseded by HK06MB061 — both numbers are cross-referenced and fulfilled with the current production equivalent. Verify your existing switch's W.C. rating and port configuration before ordering. Our HVAC parts specialists are available to confirm fitment before you buy.