Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 1-Pole 30A 24V Coil for PY4GNAB42060NA
Carrier

OEM Carrier Contactor 1-Pole 30A 24V Coil for PY4GNAB42060NA

SKU: CARRIE-PY4GNAB42060NA-CONTACTOR-HN51KC024 Brand: Carrier
Guaranteed to fit PY4GNAB42060NA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single-Pole Contactor 30A 24V Coil — HN51KC024 for Model PY4GNAB42060NA

This is the genuine OEM factory-replacement contactor for the Carrier PY4GNAB42060NA packaged unit. The contactor is the high-voltage relay that closes the compressor and condenser fan motor circuit every time your thermostat calls for cooling or heating. When the 24V control signal energizes the coil, the contacts snap closed and power flows to the load. A failed contactor is one of the most common no-cool service calls: pitted or welded contacts, a burned coil, or a chattering relay that won't pull in are the top symptoms. Replacing it with the correct OEM part restores factory-spec performance and prevents premature compressor wear.

  • Specs: 1-Pole configuration | 24 VAC coil voltage | 30A Full Load Amps (FLA) | 150A Locked Rotor Amps (LRA) | 50/60 Hz | OEM Part # HN51KC024
  • OEM vs Generic: This is the Factory Authorized Part built to exact Carrier corporation specifications. Generic contactors often use lighter-gauge contact material rated for fewer switching cycles, leading to earlier pitting, coil failure, and nuisance lockouts under high summer loads.
  • Install difficulty: 2/5 — Shut off all power at the disconnect and breaker before beginning. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring before disconnecting. Verify 24V coil pull-in after installation with a thermostat call before buttoning up the panel.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Engineered to fit Carrier model PY4GNAB42060NA packaged gas/electric and heat pump units. Cross-references: HN51CC024, P282-0311, P282-1304, P282-1305, 301362-101, 301323-101, 72930DP1. Always verify your unit's data plate before ordering — our fitment team is standing by to confirm compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY4GNAB42060NA?
Yes. This is the factory-specified OEM contactor for the Carrier PY4GNAB42060NA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY4GNAB42060NA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.