OEM Carrier Draft Inducer Pressure Switch 0.18" WC for Model PY4GNAB24060AA

This OEM draft pressure switch (part HK06WC061, now superseded by HK06MB061) is the factory-specified replacement for the Carrier PY4GNAB24060AA packaged unit. The pressure switch monitors negative pressure created by the inducer motor to confirm safe venting conditions before allowing ignition. When it fails or sticks open, the control board cannot verify that combustion gases are being properly exhausted — resulting in a hard lockout, a no-heat condition, or a system that never advances past the inducer pre-purge stage.

  • Specs: 0.18" Water Column (WC) set point | Normally open (NO) configuration | Single-port design | Replaces OEM part HK06WC061 / superseded by HK06MB061 | Cross-references Honeywell IS20224-5236 and 1938D2/B
  • OEM vs Generic: This OEM-grade switch is calibrated to the exact 0.18" WC set point required by your Carrier system. Off-spec generic switches can trip too early or too late, causing nuisance lockouts or — more dangerously — allowing ignition attempts without confirmed draft.
  • Install difficulty: 2/5 — Turn off power and gas before beginning. Tools needed: 1/4" nut driver, flathead screwdriver, needle-nose pliers. Disconnect the rubber pressure hose and two wire leads, swap the switch, and verify hose is fully seated. Always check for cracked or collapsed tubing while the unit is open.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier PY4GNAB24060AA packaged unit. Also fits a broad range of Carrier, Bryant, and Payne furnaces, packaged units, and heat pumps requiring a 0.18" WC draft pressure switch. Confirm the WC rating on your existing switch or equipment data plate before ordering. Our team is happy to verify fitment — contact us before you order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY4GNAB24060AA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY4GNAB24060AA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY4GNAB24060AA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.