Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM Carrier draft inducer pressure switch (part HK06WC061, superseded by HK06MB061) is the factory-specified replacement for the Carrier PY4GNAA48090AA packaged gas/electric unit. The pressure switch monitors negative pressure created by the inducer blower to confirm safe draft before allowing the ignition sequence to proceed. When this switch fails, the control board cannot verify that combustion gases are being properly vented, triggering a safety lockout — the most common symptom being a furnace or packaged unit that attempts to start but shuts down before the burners ever ignite.
Compatibility: Engineered for the Carrier PY4GNAA48090AA packaged unit. This switch is also used across a wide range of Carrier, Bryant, and Payne packaged and split-system equipment sharing the same inducer and draft configuration. Verify the 0.18" WC rating on your existing switch before ordering. Our fitment team is available to confirm compatibility — just reach out before you buy.