Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch 0.18 WC for PY4GEAB48115NA
Carrier

OEM Carrier Pressure Switch 0.18 WC for PY4GEAB48115NA

SKU: CARRIE-PY4GEAB48115NA-PRESSURE_SWITCH-HK06WC061 Brand: Carrier
Guaranteed to fit PY4GEAB48115NA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Draft Inducer Pressure Switch 0.18" WC for Model PY4GEAB48115NA

This is the factory-authorized OEM replacement pressure switch (part number HK06WC061, superseded by HK06MB061) for the Carrier PY4GEAB48115NA packaged unit. The pressure switch monitors negative air pressure created by the draft inducer motor, proving that safe combustion venting is established before allowing the gas valve to open. When it fails, the furnace or packaged unit will lock out on a pressure switch fault — typically before any ignition attempt — leaving you with no heat and a flashing diagnostic code.

  • Specs: 0.18" WC (water column) set point | Normally open (N/O) | Single-port hose barb | Factory-matched Honeywell cross-reference IS20224-5236 | Direct OEM replacement for HK06WC061 / HK06MB061
  • OEM vs Generic: OEM pressure switches are calibrated to the exact trip point required by your unit's inducer and heat exchanger design. Off-spec generic switches can trip too early (nuisance lockouts) or too late (unsafe venting condition), neither of which is acceptable.
  • Install difficulty: 2/5 — Power off the unit at the disconnect before starting. Tools needed: 1/4" nut driver, needle-nose pliers, and a short length of 3/16" ID tubing if the original is cracked. Always inspect the rubber hose for blockage or splits — a clogged port is the #1 cause of pressure switch failure that isn't the switch itself.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Engineered specifically for the Carrier PY4GEAB48115NA packaged gas/electric unit. Also cross-references Bryant and Payne models sharing the same inducer assembly. Verify the 0.18" WC rating on your existing switch before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you buy — contact us today and get your system back online fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY4GEAB48115NA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY4GEAB48115NA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY4GEAB48115NA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.