OEM Carrier Flame Sensor (48GS400192) for Model PY3PNA060130AA

This is the genuine OEM Carrier flame sensor, part number 48GS400192, factory-specified for the Carrier PY3PNA060130AA gas furnace. The flame sensor (also called a flame rod) uses ionization/rectification technology to confirm that a burner flame is present after the igniter fires. When this sensor fails or becomes coated with oxidation, the furnace's integrated furnace control (IFC) board can no longer verify combustion — triggering a safety lockout. The classic symptom: your furnace lights normally, runs for 5–8 seconds, then shuts off and attempts two more retries before going into hard lockout.

  • Specs: 90° angled rod design | Includes mounting bracket | Factory-matched ionization signal output | Compatible with 24VAC control circuits on Carrier gas furnaces
  • OEM vs Generic: This is a genuine Carrier OEM part — not an aftermarket substitute. OEM sensors maintain precise rod geometry and coating integrity, ensuring accurate flame signal rectification. Generic sensors often use inferior alloys that oxidize faster, leading to repeat failures within one heating season.
  • Install Difficulty: 2/5 — Turn off power and gas before servicing. Tools needed: 1/4" hex driver, needle-nose pliers, and a multimeter (to verify microamp signal if desired). A light sanding of the rod with fine steel wool can restore a marginal sensor, but replacement is always preferred for reliable operation. Photograph the wiring connector before removal.
  • Warranty: 1-year OEM manufacturer warranty against defects. Orders placed before 3 PM ship same business day from our warehouse.

Compatibility: Designed and factory-specified for the Carrier PY3PNA060130AA gas furnace. Always cross-reference the part number on your existing sensor or your unit's wiring diagram before ordering. Our fitment team is available to verify compatibility before you buy — no guesswork required. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Flame Sensor fit my Carrier PY3PNA060130AA?
Yes. This is the factory-specified OEM flame sensor for the Carrier PY3PNA060130AA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the flame sensor on my Carrier PY3PNA060130AA?
Difficulty: Easy (10–15 min)
Step 1: Turn off power/gas. Step 2: Open furnace panel. Step 3: Locate flame sensor rod near burners. Step 4: Remove single mounting screw. Step 5: Clean rod with 400-grit sandpaper until shiny (or replace). Step 6: Reinstall and tighten. Most common furnace repair — saves $150–$300 vs technician.
My furnace lights then shuts off after a few seconds. Why?
Furnace lights then shuts off after 3–10 seconds = dirty flame sensor in 90% of cases. The sensor can’t detect flame through oxidation buildup. Fix: clean with 400-grit sandpaper (free, 15 min). If cleaning doesn’t work, replace the sensor.
Is this flame sensor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier flame sensor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.