OEM Carrier Direct Spark Ignition (DSI) Control Board LH33WP003 for Model PY3PNA060115NB

This is the factory OEM Direct Spark Ignition (DSI) control board for the Carrier PY3PNA060115NB packaged rooftop unit. As the central intelligence of your furnace or rooftop heating system, this microprocessor-based board orchestrates spark ignition, gas valve activation, inducer and blower fan motor operation, flame sensing, and system-wide safety lockout. When this board fails, you'll typically experience a no-heat condition, repeated ignition attempts followed by lockout, erratic blower behavior, or a furnace that starts briefly and then shuts down entirely. Replacing it with the correct OEM part restores factory-calibrated timing sequences and full diagnostic capability.

  • Specs: Direct Spark Ignition (DSI) | Microprocessor-based design | Pre-purge: 45 sec | Trial for Ignition: 5+2 sec | Retry period: every 20 sec for 15 min | Manual-reset lockout | Post-purge: 45 sec | Onboard LED fault code diagnostics | Dimensions: 5 × 7 × 1.875 in
  • OEM vs Generic: This is the genuine Carrier OEM board (LH33WP003), manufactured to exact factory specifications. Generic aftermarket boards may not replicate proprietary timing sequences or LED fault code logic, potentially causing nuisance lockouts, voided equipment warranties, and incorrect safety shutdowns. Always use OEM when servicing commercial rooftop units where liability and uptime matter.
  • Install Difficulty: 3/5 — Shut off power and gas before beginning. Photograph all wiring harness connections prior to removal. Tools needed: #2 Phillips screwdriver, 1/4" nut driver, multimeter (to verify 24V control circuit), and a camera or phone for reference photos. Verify all limit switches and pressure switch wiring are re-seated firmly before restoring power. First-time board replacement recommended for experienced technicians.
  • Warranty: 1-year OEM manufacturer warranty. In-stock — ships same business day from our warehouse.

Compatibility: Designed for the Carrier PY3PNA060115NB packaged rooftop unit. Also referenced under part number LH33WP003A. Verify your unit's data plate and existing board part number before ordering. Our fitment specialists are available to confirm compatibility prior to purchase — same-day shipping available on all in-stock orders placed before 3 PM.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier PY3PNA060115NB?
Yes. This is the factory-specified OEM control board for the Carrier PY3PNA060115NB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier PY3PNA060115NB?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.