Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 24V Coil 2-Pole for PY3PNA030060AB
Carrier

OEM Carrier Contactor 24V Coil 2-Pole for PY3PNA030060AB

SKU: CARRIE-PY3PNA030060AB-CONTACTOR-HN51KB024 Brand: Carrier
Guaranteed to fit PY3PNA030060AB — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Contactor 24V Coil 2-Pole for Model PY3PNA030060AB

This OEM contactor (part number HN51KB024) is the factory-specified high-voltage switching relay for the Carrier PY3PNA030060AB packaged unit. The contactor acts as the primary electrical bridge between the 24V thermostat control signal and the high-voltage compressor and condenser fan circuits. When a contactor fails, the most common symptoms are an air conditioning system that simply won't turn on, a system that hums but never starts, or pitted/burned contact points that cause intermittent cooling or tripped breakers.

  • Specs: 2-pole configuration | 24V AC coil voltage | Factory OEM replacement | Matches original contact amp rating for PY3PNA030060AB packaged unit — verify amperage on data plate before ordering
  • OEM vs Generic: This OEM Carrier contactor uses factory-grade contact materials rated for the exact load of your unit. Generic contactors frequently use lower-grade alloys that pit and weld prematurely under high-cycle summer loads, leading to repeat failures within one season.
  • Install Difficulty: 3/5 — High voltages are present inside the disconnect panel. Always shut off power at the disconnect and verify zero voltage with a multimeter before touching any terminals. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring before disconnecting.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed by 3 PM ship the same business day from our warehouse.

Compatibility: Engineered specifically for the Carrier PY3PNA030060AB packaged unit. Always confirm coil voltage (24V) and pole count on your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — contact us anytime.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY3PNA030060AB?
Yes. This is the factory-specified OEM contactor for the Carrier PY3PNA030060AB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY3PNA030060AB?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.