OEM Carrier Single Run Capacitor 4 MFD & 25 MFD 370V — PY3PEA060130NA
Carrier

OEM Carrier Single Run Capacitor 4 MFD & 25 MFD 370V — PY3PEA060130NA

SKU: CARRIE-PY3PEA060130NA-CAPACITOR-P291-0403 Brand: Carrier
Guaranteed to fit PY3PEA060130NA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Single Run Capacitor Kit (P291-0403 & P291-2503) for Model PY3PEA060130NA

This factory-matched OEM single run capacitor set includes both the P291-0403 (4 MFD 370V) and P291-2503 (25 MFD 370V) oval run capacitors — the factory-specified replacements for the Carrier PY3PEA060130NA packaged unit. Run capacitors store and discharge the electrical energy required to keep the fan motor and compressor running at peak efficiency. When a run capacitor weakens or fails, you'll typically notice symptoms such as motors that hum but won't start, systems that short-cycle, warm air output despite the unit running, or a complete motor failure. Replacing with OEM-spec capacitors restores factory performance and protects expensive downstream components.

  • Specs: P291-0403 — 4 MFD (microfarad) | 370V | Oval case | 50/60Hz | P291-2503 — 25 MFD | 370V | Oval case | 50/60Hz | High-grade metallized polypropylene film dielectric | RoHS compliant
  • OEM vs Generic: These are genuine Carrier Totaline OEM capacitors, reliability-tested to 60,000 service hours per United Technologies specifications. Generic alternatives often carry wider MFD tolerances (±10%), which accelerates motor wear and can void equipment warranties.
  • Install difficulty: 2/5 — Shut off all power and discharge capacitors before handling — stored charge can cause serious injury. Tools needed: 1/4" nut driver, insulated needle-nose pliers, multimeter with capacitance function. Always photograph existing wiring orientation before disconnecting terminals.
  • Warranty & Shipping: 1-year OEM factory warranty on both capacitors. UL approved with patented pressure-sensitive interrupter. Orders ship same business day from our warehouse.

Compatibility: Engineered as the direct OEM replacement for Carrier PY3PEA060130NA packaged units. Also replaces legacy part numbers HC90AA004, HC91CA004, and HC90AB004. Always verify the MFD rating and voltage on your unit's data plate before ordering to confirm fitment. Have questions? Our HVAC parts specialists verify compatibility before you order — contact us for fast, expert assistance.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Capacitor fit my Carrier OEM Carrier Single Run Capacitor 4 MFD & 25 MFD 370V — PY3PEA060130NA?
Yes. This is the factory-specified OEM capacitor for the Carrier OEM Carrier Single Run Capacitor 4 MFD & 25 MFD 370V — PY3PEA060130NA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the capacitor on my Carrier OEM Carrier Single Run Capacitor 4 MFD & 25 MFD 370V — PY3PEA060130NA?
Difficulty: Easy (20–30 min)
Step 1: Turn off power at breaker. Step 2: Open condensing unit panel. Step 3: Photograph the old capacitor wiring (Common/Herm/Fan). Step 4: Discharge old capacitor with insulated screwdriver. Step 5: Disconnect and remove old capacitor. Step 6: Mount new capacitor, reconnect wires to matching terminals. Step 7: Close panel, restore power, test. Tools: screwdriver, needle-nose pliers.
My AC hums but won’t start. What part do I need?
An AC that hums but won’t start is the classic symptom of a failed capacitor. The capacitor provides the electrical boost to start the compressor. When it fails, you hear humming but the motor can’t overcome inertia. Other symptoms: fan spinning slowly, AC cycling on/off rapidly, or a visibly swollen capacitor. Fix: replace capacitor ($15–$80 DIY, 30 min).
Is this capacitor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier capacitor?
OEM strongly recommended. OEM capacitors have ±6% MFD tolerance vs aftermarket ±10%. The looser tolerance causes motor winding stress, higher temps, and shorter compressor life. Price difference is only $10–$20 — OEM is the clear value choice.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.