Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier 2-Pole Contactor 30 Amp 24V for PY3PEA042060NB
Carrier

OEM Carrier 2-Pole Contactor 30 Amp 24V for PY3PEA042060NB

SKU: CARRIE-PY3PEA042060NB-CONTACTOR-HN52KC025 Brand: Carrier
Guaranteed to fit PY3PEA042060NB — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 30 Amp 24V Coil for Model PY3PEA042060NB (Replaces HN52KC025)

This OEM 2-pole contactor is the factory-authorized replacement for the Carrier PY3PEA042060NB condensing unit, replacing discontinued OEM part number HN52KC025. The contactor is the high-voltage switching relay that your thermostat's 24V control signal energizes to connect line voltage to the compressor and condenser fan motor. When the contactor fails, you'll typically experience an AC unit that won't turn on at all, hums without starting, chatters repeatedly, or — in the case of welded contacts — runs continuously and won't shut off.

  • Specs: 2-Pole (Double Pole) | 30 Amp FLA | 24V AC Coil | 50/60 Hz | 600V rated load side | Direct OEM replacement for HN52KC025
  • OEM vs Generic: OEM contactors are manufactured to exact Carrier coil pull-in voltage specs and contact gap tolerances. Generic units frequently use thinner contact material that pits and welds faster under high compressor inrush current, shortening service life significantly.
  • Install Difficulty: 2/5 — Always disconnect power at the breaker and capacitor before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor. Swap wires one at a time to prevent miswiring.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse.

Compatibility: Fits Carrier model PY3PEA042060NB condensing units. OEM part number HN52KC025 has been superseded — this is the current factory-approved direct replacement. Always verify the coil voltage (24V) and pole count (2-pole) on your unit's data plate or existing contactor before ordering. Our team is available to confirm fitment prior to purchase.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier PY3PEA042060NB?
Yes. This is the factory-specified OEM contactor for the Carrier PY3PEA042060NB. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier PY3PEA042060NB?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera