This is the OEM-specified draft inducer pressure switch for the Carrier PY3GPAA60090AA packaged gas unit. The pressure switch is a critical safety device that monitors negative pressure created by the inducer motor to confirm proper venting before allowing ignition. When it fails or sticks open, the control board cannot verify safe flue conditions and will lock out the system — preventing any heat from being produced. Common symptoms include a furnace that attempts to start but shuts down before ignition, a blinking fault code indicating "pressure switch open," or a unit that runs the inducer continuously without progressing to the heating cycle.
Compatibility: Designed for the Carrier PY3GPAA60090AA packaged gas/electric unit. Also fits select Bryant and Payne models sharing this 0.18" WC switch specification — verify the rating on your existing switch or equipment data plate before ordering. Note: HK06WC061 has been superseded by HK06MB061; both part numbers are fulfilled by this listing. Questions about fitment? Our HVAC parts specialists confirm compatibility before every order.