Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch HK06WC061 for PY3GNAA24040NA
Carrier

OEM Carrier Pressure Switch HK06WC061 for PY3GNAA24040NA

SKU: CARRIE-PY3GNAA24040NA-PRESSURE_SWITCH-HK06WC061 Brand: Carrier
Guaranteed to fit PY3GNAA24040NA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch HK06WC061 for Model PY3GNAA24040NA

This is the factory OEM replacement pressure switch (part number HK06WC061) for the Carrier PY3GNAA24040NA gas furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor. It confirms that proper venting airflow exists before allowing the control board to advance the ignition sequence. When this switch fails — or when the hose, port, or inducer itself causes it to read incorrectly — the furnace will lock out prior to ignition, often displaying a pressure switch fault code and leaving your home without heat.

  • Specs: OEM part number HK06WC061 | Factory-calibrated W.C. (water column) set point | Single-port design | 24V control circuit rated | Direct OEM fit, no modification required
  • OEM vs Generic: This is a genuine Carrier OEM pressure switch, precision-calibrated to the exact W.C. rating required by the PY3GNAA24040NA. Generic substitutes are often rated at approximate set points, risking nuisance lockouts or, worse, unsafe venting conditions that a mis-calibrated switch fails to detect.
  • Install Difficulty: 2/5 — A straightforward swap for experienced DIYers or technicians. Tools needed: flat-head and Phillips screwdrivers, needle-nose pliers, multimeter (to confirm continuity before and after). Always shut off gas and power before servicing. Inspect the rubber hose and inducer port for blockages or cracks — these cause most pressure switch failures and should be replaced if damaged.
  • Warranty: 1-year OEM factory warranty against defects. In-stock units ship same business day from our warehouse when ordered before cutoff.

Compatibility: Engineered as a direct OEM replacement for Carrier model PY3GNAA24040NA. Always cross-reference the W.C. rating printed on your existing switch with the HK06WC061 specification before installing. If you are unsure of fitment, our HVAC parts specialists are available to verify compatibility before you order — same-day shipping available on all in-stock parts.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY3GNAA24040NA?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY3GNAA24040NA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY3GNAA24040NA?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online