This OEM draft inducer pressure switch is the factory-specified replacement for the Carrier PY3GNA060130NA gas furnace. The pressure switch monitors negative pressure created by the inducer blower motor at startup, confirming that combustion gases are being safely vented before allowing the ignition sequence to proceed. When this switch fails or sticks open, the furnace control board never receives proof of draft — resulting in a hard lockout before the burners ever fire. Common symptoms include a furnace that runs the inducer motor but never advances to ignition, flashing fault codes indicating an open pressure switch, or a system that locks out after 3 attempts.
Compatibility: Designed for Carrier model PY3GNA060130NA gas furnace. This part supersedes original OEM part number HK06WC061; the current shipping part is HK06MB061 — both are fully interchangeable. Also cross-references Honeywell part numbers IS20224-5236 and 1938D2/B. Confirm the 0.18" W.C. rating on your existing switch before ordering. Questions about fitment? Our HVAC parts specialists verify compatibility before you buy — ships today.