Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA
OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA
OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA
OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA
Carrier

OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA

SKU: CARRIE-PY3GNA060115NA-CONTROL_BOARD-LH33WP007 Brand: Carrier
Guaranteed to fit PY3GNA060115NA — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Ignition Control Board 24V 60Hz for Model PY3GNA060115NA

This OEM ignition control board (part number LH33WP007) is the factory-specified replacement for the Carrier PY3GNA060115NA gas furnace. The integrated furnace control (IFC) board is the brain of your heating system — it sequences every stage of the heating cycle, from inducer startup and pressure switch verification to hot surface ignition, flame sensing, and blower operation. When the board fails, symptoms typically include a hard lockout with no ignition attempt, intermittent no-heat calls, or fault codes indicating a control board failure on your thermostat or diagnostic LED display.

  • Specs: 24V control voltage | 60Hz | OEM part number LH33WP007 | Factory-matched timing and sequencing parameters for the PY3GNA060115NA platform
  • OEM vs Generic: This is the genuine Carrier OEM board — not an aftermarket substitute. OEM boards retain factory-programmed timing sequences, fault-code logic, and safety lockout thresholds. Generic boards can introduce mismatched timing that leads to nuisance lockouts or, worse, unsafe combustion sequences.
  • Install Difficulty: 4/5 — Control board replacement requires shutting off gas and 120V power, photographing all wiring harness connections before removal, and carefully transferring each connector to the new board. A multimeter is recommended to verify 24V to the board before assuming board failure. Always clear fault history after installation.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Engineered specifically for the Carrier PY3GNA060115NA gas furnace. Cross-references with board number 1068-15. Verify your existing board's part number against LH33WP007 before ordering. Have questions about fitment? Our HVAC parts team confirms compatibility before you buy — same-day shipping available on all in-stock orders.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Ignition Control Board 24V 60Hz — PY3GNA060115NA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online