Secure Checkout
This is the OEM factory-specified flame sensor for the Carrier PY3GNA060090NB gas furnace. The flame sensor — also called a flame rod — is a critical safety component mounted in the burner assembly. Using ionization/rectification technology, it detects the presence of a live burner flame and sends a microamp signal to the control board confirming ignition. If the signal is absent or too weak (typically due to oxidation or carbon buildup on the rod), the control board will shut off the gas valve within 5–8 seconds of each ignition attempt, triggering a lockout fault. Replacing the sensor with the correct OEM part restores proper signal strength and eliminates nuisance lockouts.
Compatibility: Designed for the Carrier PY3GNA060090NB gas furnace. Verify OEM part number 48GS400192 on your existing sensor or equipment data plate before ordering. Not sure it fits? Our HVAC parts specialists verify fitment before you buy — order today and your part ships the same business day.