OEM Carrier Pressure Switch 0.18
Carrier

OEM Carrier Pressure Switch 0.18" WC for PY3GNA060090NA — HK06WC061

SKU: CARRIE-PY3GNA060090NA-PRESSURE_SWITCH-HK06WC061 Brand: Carrier
Guaranteed to fit HK06WC061 — or your money back. Terms

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Draft Inducer Pressure Switch 0.18" WC for Model PY3GNA060090NA

This OEM pressure switch (part number HK06WC061, superseded by HK06MB061) is the factory-specified draft inducer pressure switch for the Carrier PY3GNA060090NA gas furnace. Its job is to verify that the inducer motor is creating sufficient negative pressure (draft) before allowing the ignition sequence to proceed — a critical safety function. When this switch fails or sticks open, the furnace will lock out before any ignition attempt, leaving you with a no-heat call. Common symptoms include a blinking fault code for "pressure switch open," an inducer motor that runs but never advances to ignition, or a furnace that cycles the inducer repeatedly without lighting.

  • Specs: 0.18" W.C. (water column) set point | Normally open, closes on negative pressure | Single-port hose barb | Compatible with Carrier, Bryant, and Payne furnace platforms | Cross-references Honeywell IS20224-5236
  • OEM vs Generic: This is a genuine OEM Carrier part, factory-calibrated to the exact 0.18" W.C. threshold required by the PY3GNA060090NA. Generic switches often carry wider tolerance bands that can cause nuisance lockouts or — more dangerously — fail to detect a blocked flue condition.
  • Install Difficulty: 2/5 — Turn off power and gas before beginning. Tools needed: #2 Phillips screwdriver, 1/4" nut driver, and needle-nose pliers to remove the rubber pressure hose. Inspect the hose for cracks or blockages while the switch is out. Reconnect the single wire harness and hose barb, then restore power and test.
  • Warranty: 1-year OEM factory warranty. Orders ship same business day from our warehouse when placed before cutoff.

Compatibility: Designed for the Carrier PY3GNA060090NA packaged gas/electric unit. This part is also cross-referenced under successor part number HK06MB061 and Honeywell IS20224-5236 / 1938D2/B. Always confirm the 0.18" W.C. rating on your unit's existing switch before ordering. Our HVAC parts specialists are available to verify fitment — contact us before you order if you have any questions.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY3GNA060090NA — HK06WC061?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY3GNA060090NA — HK06WC061. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY3GNA060090NA — HK06WC061?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.