This OEM pressure switch (part number HK06WC061, superseded by HK06MB061) is the factory-specified draft inducer pressure switch for the Carrier PY3GNA060090NA gas furnace. Its job is to verify that the inducer motor is creating sufficient negative pressure (draft) before allowing the ignition sequence to proceed — a critical safety function. When this switch fails or sticks open, the furnace will lock out before any ignition attempt, leaving you with a no-heat call. Common symptoms include a blinking fault code for "pressure switch open," an inducer motor that runs but never advances to ignition, or a furnace that cycles the inducer repeatedly without lighting.
Compatibility: Designed for the Carrier PY3GNA060090NA packaged gas/electric unit. This part is also cross-referenced under successor part number HK06MB061 and Honeywell IS20224-5236 / 1938D2/B. Always confirm the 0.18" W.C. rating on your unit's existing switch before ordering. Our HVAC parts specialists are available to verify fitment — contact us before you order if you have any questions.