OEM Carrier Draft Pressure Switch 0.18" WC for Model PY3GNA048115NA (HK06WC061 / HK06MB061)

This OEM Carrier draft pressure switch is the factory-specified replacement for the Carrier PY3GNA048115NA packaged unit. The pressure switch monitors negative pressure created by the inducer motor to confirm proper venting before allowing ignition. When it fails or sticks open, the control board cannot prove a safe flue draft and will lock out the system — leaving you with no heat and often a fault code pointing to inducer or pressure-switch failure.

  • Specs: 0.18" Water Column (W.C.) set point | SPST (Single Pole, Single Throw) | OEM Part # HK06WC061, updated successor # HK06MB061 | Also cross-references Honeywell IS20224-5236
  • OEM vs Generic: OEM pressure switches are calibrated to exact W.C. tolerances at the factory. An off-spec generic switch can cause nuisance lockouts or, worse, allow ignition attempts under unsafe draft conditions — always match the W.C. rating precisely.
  • Install difficulty: 2/5 — Power down and confirm the system is off before starting. Disconnect the rubber hose from the inducer port and the two spade terminals. Swap the switch, reconnect hose and terminals, and restore power. Tools needed: flathead screwdriver, needle-nose pliers. Check for cracked hose tubing while you're in there.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed for the Carrier PY3GNA048115NA packaged unit. OEM part number HK06WC061 has been superseded by HK06MB061 — both are covered by this listing and are direct drop-in replacements. Also fits select Bryant and Payne models sharing this inducer/pressure-switch assembly. Verify the 0.18" W.C. rating on your existing switch before ordering. Need fitment confirmation? Our HVAC parts team will verify compatibility before you buy.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $99
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier PY3GNA048115NA — HK06WC061?
Yes. This is the factory-specified OEM pressure switch for the Carrier PY3GNA048115NA — HK06WC061. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier PY3GNA048115NA — HK06WC061?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.